Wall Layout

L — H — 8 × 8 × 16 CMU
Enter a wall length and height to see the layout.
Wall elevation is schematic. Course lines, openings and supports update as project information is entered.

Enter Wall Information

ft
in
ft
in

Mortar joint included: Standard CMU calculations use nominal installed dimensions, which include the typical 3/8" mortar joint.

Custom Nominal Block Module
in
in
in

Openings

Add doors, windows, gates or other openings to deduct their approximate CMU area.

Pilasters / Columns

Pilaster / Column Layout
ft
in
in
Integrated Pilaster Material

The normal wall block is already included in the base wall. Enter only the extra CMU required to build the thicker pilaster at each course.

Freestanding Column Material

If overall length is selected, the calculator subtracts the column widths from the base wall-panel length before calculating wall blocks.

Additional Material

Optional allowance for corners, cuts, half blocks, jamb units, bond-beam units or other specialty CMU.

%

Wall System Results

Wall Panel Length Used —
Gross Wall Panel Area 0.00 ft²
Required Courses 0
Blocks per Course 0.00
Modular Height —
Partial Top Course —
Gross Wall Blocks 0.00
Opening Deduction 0.00
Calculated Supports 0
Pilaster / Column Blocks 0.00
Net Units Before Waste 0.00
Waste / Overrun 0.00
Estimated Blocks to Purchase 0 blocks

Integrated pilasters add only the additional CMU beyond the normal wall plane. Freestanding columns are calculated separately from the wall panels. Actual bond patterns, corners, jambs and specialty units may change the final material quantities.

CMU Wall Reference

Nominal vs. Actual Block

Standard CMU layout uses nominal installed dimensions. A nominal 8 × 8 × 16 block is commonly approximately 7-5/8 × 7-5/8 × 15-5/8 inches before the mortar joint.

The approximately 3/8-inch mortar joint brings the installed module to about 8 inches high by 16 inches long.

Integrated Pilaster

An integrated pilaster is bonded into the wall. The normal wall face is already included in the base wall quantity.

The pilaster input therefore adds only the extra units required per pilaster per course, preventing the wall block from being counted twice.

Freestanding Column

A freestanding column is calculated separately from the wall panel. Enter the number of blocks used in one column for each course.

When the entered wall length includes the columns, select Overall Length Including Columns so their widths are deducted from the wall-panel length.

Support Spacing

Spacing mode places interior supports at the selected maximum spacing and allows either or both wall ends to contain a support.

This is a material-layout tool. It does not determine structurally required pilaster or column spacing.

Openings

Doors, windows and gates are deducted by their nominal opening area. Jambs, lintels, bond beams and cut units can cause the actual block usage to differ from the simple area deduction.